|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
Specification AXIS100-03 Oscillator type : VCXO Parameter Frequency range Standard frequencies Frequency stability Initial tolerance vs. temperature in operating temperature range (-10~+60C) vs. supply voltage variation vs. load change long term (aging) Frequency adjustment range Electronic Frequency Control (EFC) range @ 25C EFC voltage VC EFC slope (f / VC) EFC linearity Control bandwidth RF output Signal waveform Amplitude Harmonics attenuation Subharmonics attenuation Nonarmonics attenuation Supply voltage VS Current consumption (steady state) Operable temperature range Storage temperature range Enclosure (see drawing) LxWxH Issue: 03 Date: 2005-06-10 min. typ. 38,900 max. Unit MHz MHz ppm ppm ppm Condition 100 100 @VC = 0V -20 60 -10 negative 3 30 SINUS +0 30 40 50 11,4 20 ppm ppm ppm/year @ 40C kHz 10 V % KHz RL = 50 +3 12,6 60 -20 +70 -40 +85 36.1x27.2x10.5 max. 12 dBm dBc dBc dBc V mA C C mm Similar to IEC 60679-3 CO 09 20 gram Weight bulk IEC 60286-3 Packing 1500 V HBM, IEC 61000-4-2 ESD Sensitivity Notes: 1. Terminology and test conditions are according to IEC standard IEC60679-1, unless otherwise stated Ordering Code: Model (Specification) AXIS100-03 Frequency [MHz] 38,900 GmbH & Co. KG Wasemweg 5 D-74821 Mosbach Germany AXIS100-03 page 1(2) www.axtal.com fon: +49 (6261) 939834 fax: +49 (6261) 939836 E-mail: info@axtal.com Enclosure drawing Pin connections Pin # Symbol 1 GND 2 VS 3 VC 4 GND 5 RF OUT Function Ground Supply Voltage Control Voltage (EFC) Ground RF Output Environmental conditions Test Visual inspection, dimensions Sealing tests (if applicable) Solderability Resistance to soldering heat Shock* Bump* Free fall* IEC 60068 Part ... IEC 60679-1 clause ... 4.3 4.6.2 4.6.3 Test conditions Enclosure styles as in IEC 60679-3 or 61837, if applicable Gross leak: Test Qc, Fine leak: Test Qk Test Ta (235 5)C Method 1 Test Tb Method 1A, 5s Test Ea, 3 x per axes 100g, 6 ms half-sine pulse Test Eb, 4000 bumps per Axes, 40g, 6 ms Test Ed procedure 1, 2 drops from 1m height Test Fc, 30 min per axes, 10 Hz - 55 Hz 0,75mm; 55 Hz - 2 kHz, 10g Test Na, 10 cycles at extremes of operating temperature range Test Ba, 16 h at upper temperature indicated by climatic category Test Db variant 1 severity b), 55C/95% r.H., 6 cycles Test Aa, 2 h at lower temperature indicated by climatic category Sequence of 4.6.14, 4.6.15 (1st cycle), 4.6.16, 4.6.15 (5 cycles) Test Ca, 56 days 2-17 2-20 2-58 2-27 2-29 2-32 4.6.8 4.6.6 4.6.9 4.6.7 Vibration, sinusoidal* 2-6 Rapid change of temperature Dry heat Damp heat, cyclic* Cold Climatic sequence* Damp heat, steady state* Endurance tests - ageing - extended aging 2-14 2-2 2-30 2-1 1-7 2-3 4.6.5 4.6.14 4.6.15 4.6.16 4.6.17 4.6.18 4.7.1 4.7.2 30 days @ 85C, OCXO @25C 1000h, 2000h, 8000h @85C GmbH & Co. KG Wasemweg 5 D-74821 Mosbach Germany AXIS100-03 page 2(2) www.axtal.com fon: +49 (6261) 939834 fax: +49 (6261) 939836 E-mail: info@axtal.com |
Price & Availability of AXIS100-03 |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |